One finds before buying on the Internet Unfortunately, online version of the manual.
(The then there only on paper, if you have purchased the product)
So here's a brief overview of the functions:
After mounting it triggers an adaptation mode. This is necessary so that the thermostat can make open the valve open during the normal operation accurately in 5% increments from 0% to 100%. In adaptive mode, the thermostat automatically emittelt the pressure points of the valve pin. It tried this so far as to press it in until it is pending. It is at the beginning sufficient distance between the plunger of the thermostat and the valve plug. The first pressure point is detected when the plunger on the valve plug hits (100% open). The second pressure point is detected when the engine of the thermostat is present (0% open)
There are in these radiator thermostats a variety of programming options.
# Controls for programming are the 3 keys and the large rotary knob for adjusting the values
# It can be programmed 7 temperature changes for every day. Here you can adjust for each Urhzeit and temperature.
# You can also programming for day groups Mon-Sun Sat-Sun Mon-Fri make together
# Three main modes are available:
- Automatic: The programmed temperatures are followed
- Manual: A temperature lässst with the rotary knob to adjust
- Holidays / Party: The automatic mode is temporarily superimposed up to an adjustable time and date with an adjustable temperature
# There are additionally 2 presettable temperatures for day / night that can be skipped very quickly by simply pressing a key.
# If you select the day / night button or the rotary knob while the automatic mode, a manual temperature, so this is triggered immediately. Starting next programmed time, however, the thermostat followed again the programming.
# Window on recognition: A strong drop in temperature is detected automatically. The thermostat automatically responds with a decrease in temperature for a certain period. Temperature and period are programmable.
# Summer Winter time detection: Here you can set whether the device automatically switches between summer and winter time
# Temperature offset: From within the room temperature differences can occur. The thermostat measures the temperature but only with their own sensor. You can set a temperature offset of -3.0 ° C to +3.0 ° C To compensate for this measurement error
# Reset to factory settings: This will reset everything and the unit is in automatic installation mode to adapt to a new radiator valve.
# Position: There is a programming menu in the dei currently commanded position of the valve is angzeigt in percen.
Disadvantages:
# The Window to function reacts in my opinion a bit too sluggish. Because it can sometimes has 10min detected the temperature fall take up the instrument. When something really needed it would be better to use thermostatic valves with window contact.
# There is no way of programming / control via radio transmission. So you have to adjust ran directly to the thermostats. For example, since the Heizkörperventilanschüsse are arranged in some situations that the display is then read upside down, it can be quite costly. However, one can assemble here every possible angle adapters and extensions between radiator thermostat and valve. This one brings the thermostat quickly in the desired location and position.