Therefore, we had a line from the heat storage place for our pool, where we give means of heat exchangers, the solar heat to the bath water. So far so good.
After the circulation pump of the pool now can not know when the heating is hot water, I had this past summer the pool pump always run if there was a possibility that the solar system supplied heat. The electricity bill was accordingly.
Since it could not stay that way, I decided the pool pump on the flow temperature of the heating switch. Whenever the temperature at the sensor, which is applied to the copper tube of the flow line, exceeds a value of 45 ° C, then the pump switches on. Once the temperature drops below the set switch-off value of 35 ° C, the pump switches off again.
+ Precision adjustment to 0.1 ° Celsuis
+ Input and switch-off temperature can be entered (no preset hysteresis)
+ Sufficiently long line of the probe
+ Also works very well as a contact sensor (must only properly clamped with cable ties to the cable are)
+ High switching capacity
So far, I could say anything negative about this thermostat switch.